Appearance
Inspection plan
Also known as
- new inspection plan
- characteristic
- measurement
- pass fail
- visual check
- nominal
- tolerance
- spec limits
- USL
- LSL
On the plan page you define what an inspector checks: the item, vendor or operation it applies to, the sampling rule and each characteristic with its limits.
Create a plan
- Open QualityInspection plans and select New plan.
- Under Plan, enter the Code and Name and choose the Type.
- Pick the Item, and a Vendor for a vendor-specific plan (A vendor plan takes precedence for that vendor.), or the Operation name for an in-process plan. Leave Active on.
- Under Sampling rule, choose Sampling and its value, the Minimum sample and Maximum sample, and the Accept number (defects allowed in the sample).
- Under the characteristics grid, select Add characteristic for each check (at least one).
- Select Create plan (or Save plan on an existing one). The message Plan … saved appears.
Fields
| Field | What to enter |
|---|---|
| Code, Name | Identification (required). |
| Type | Receiving, In-process or Final (required). |
| Item / Vendor / Operation | What the plan applies to. A plan must name an item, a vendor or an operation. |
| Active | Only active plans are used. |
| Description | Free text. |
| Sampling | Every unit, Fixed sample (Units to sample), Percent of lot or Square root of lot. |
| Minimum sample / Maximum sample | Bounds of the sample size. |
| Accept number | Defects allowed; more defects fail the inspection. |
Characteristics:
| Column | What to enter |
|---|---|
| Characteristic | What is checked, for example Outside diameter. |
| Type | Measurement, Pass / fail or Visual. |
| Unit, Nominal | The unit and target value of a measurement. |
| Lower limit / Upper limit | The specification limits; a measurement needs at least one. |
| Readings | Readings per inspection (1 to 25). They are the subgroup of the SPC charts. |
| Critical | A failure fails the whole inspection regardless of the accept number. |
| Instrument | The gauge used, from Calibration. |
Changing characteristics raises the Revision; characteristics keep their history for SPC. The header shows Used by … inspections. Delete plan removes it: existing inspections keep their results, new receipts are no longer held by it.