Appearance
SPC charts
Also known as
- SPC
- statistical process control
- control chart
- X-bar R
- xbar
- individuals chart
- I-MR
- Cp
- Cpk
- process capability
SPC control charts plot the measurements recorded on inspections, one subgroup per inspection, so you can see a process drift before it produces bad parts. Quality engineers use them to watch critical dimensions and process capability.
Read a control chart
- Open QualitySPC charts.
- Pick the Characteristic (each measurement characteristic of an inspection plan with readings; the list shows how many subgroups each has).
- Optionally narrow the Period and choose how many Subgroups to show (Last …).
- Choose the chart: X-bar / R (several readings per inspection) or Individuals (one reading per inspection).
You see two charts: the X-bar chart (or Individuals chart) of the subgroup means, with Centre line, Upper control limit, Lower control limit and the specification limits, and below it the Range chart (or Moving range chart). Points that break a rule are marked.
The Process panel shows Subgroups, Subgroup size, Readings, Mean, Sigma (within), the Centre line and control limits, the Specification, Cp, Cpk and the number of Out-of-control points. Rules applied lists the rules, and Out-of-control points lists each point with its inspection and the Rules broken. No measurements recorded yet. means no inspection has recorded readings for any measurement.
The rules
| Rule | A point is flagged when |
|---|---|
| Rule 1 | One point is beyond the 3σ control limits. |
| Rule 2 | 2 of 3 points in a row are beyond 2σ on the same side. |
| Rule 3 | 4 of 5 points in a row are beyond 1σ on the same side. |
| Rule 4 | 8 points in a row are on one side of the centre line. |
| Rule 5 | 6 points in a row rise or fall. |
The range and moving range charts use rule 1 only. Control limits are calculated from the data shown (X-bar ± A2·R̄, or X̄ ± 2.66·MR̄); Cp and Cpk compare the spread with the specification limits. A Cpk below 1.33 usually calls for action; raise a CAPA when the process is out of control.
The default chart type is set in General.
Related
- Inspection plan: characteristics, limits and readings
- Inspection
- CAPA
- Plan to produce